Astroflame Products

Approved Document B
- Fire Safety & Compartmentation

Astroflame Homepage

FIRE PROTECTING VOIDS AND OPENINGS - Approved Document B

Building Regulations - Approved Document BApproved Document B requires fire compartmentation be maintained where service pipes and ducts penetrate fire walls. Astroflame products restore fire resistance as required by Approved Document B in a simple, effective and reliable manner.

What Approved Document B states:

Openings in other Compartment Walls or Compartment Floors should be limited to those for the passage of pipes, ventilation ducts, chimneys, appliance ventilation ducts or ducts encasing one or more flue pipes, which meet the provisions in Section 10 ... Every joint or imperfection of fit, or opening to allow services to pass through the element, should be adequately protected by sealing or fire-stopping so that the fire resistance of the element is not impaired.

Openings for pipes and ducts passing through a fire-separating element must be protected using a proprietary sealing system which has been shown by test to maintain the fire resistance of the wall, floor or cavity barrier.

Where ventilation ducts, flues etc. pass through fire separating elements the integrity of those
elements should be maintained using fire dampers or fire-resisting enclosures or fire-resisting
ductwork.

FIRE CERTIFICATION:

Testing standards that apply to fire protection products for pipework, ductwork and voids are:

Penetration sealing systems BS476: Part 20 and 22
Fire resistant ductwork BS476: Part 20 and 24Independent certification of fire protection products.
Fire dampers BS EN 1366-2

Fire protection products we supply are variously independently certified to BS and EN standards and / or have NHBC type approvals.

Astroflame has ISO 9001 Certification

Below are links to detailed product information for some of the fire protection product range meeting the requirements of Approved Document B Section 10: for maintaining fire compartmentation. This includes pipe and duct wraps, pipe and duct sleeves, fire clamps and intumescent sealing materials.

Download Astroflame Product Guides (PDF's)

Fire Protection Brochure
Mechanical Electrical Brochure
Fireproof-Paint-Brochure

Fire Stopping

Socket Box Inserts

Fireproof Paints

 

Selected Astroflame Fire Protection Products:

Quad Seal
Fire, Smoke, Acoustic
& Draught seal

Quad seal

Intumescent Fireseals

Intumescent fireseal image

Intumescent Smoke Seals

Smoke Seals

Intumescent Duct Wrap

Intumescent duct wrap

Duct Sleeve

Intumescent duct sleeve

Cable Tray Sleeve

Fire resistant cabler tray sleeve

Intumescent Pipe Wrap

Intumescent Pipe Wrap image

Acoustic Vent Sleeve

Fire resistant acoustic vent sleeve

Socket Box Cover

Intumescent putty pad.  Dry wall socket box cover

Socket Box Insert

Intumescent socket box insert.

Intumescent Acoustic Mastic

Intumescent and acoustic mastic

Fire Rated Acoustic Foam

Fire Rated and Acoustically tested construction foam

 

Approved Document B, E and MAll of the fire stopping products above are suitable for new installation or retrofit and some are acoustically tested as well as fire tested so they meet the requirements of Approved Document B and Approved Document E

Products are added or updated on a regular basis so check back here from time to time or visit astroflame.com where the full range of products is presented.

 

For further information or to discuss your requirements email sales@astroflame.com or phone us.

Astroflame (Fire Seals) Ltd. Intumescent House
Unit 8, The IO Centre, Stephenson Road, Segensworth
FAREHAM, ENGLAND PO15 5RU
tel 0800 023 2482
(01329 844500)
fax 0800 023 2483
(01329 844600)
intl
tel +44 1329 844500
fax +44 1329 844600

 

Top of Page